Skip to main content

CU-PASS-SOL

Material Specific

Composition

CuSO₄·5H₂O + H₂SO₄ in water (acidic Cu passivation)

PACE recipe, supplied ready-to-use

Method

Immersion (post-etch passivation)

Time

5–10 s

Alternative Names

Copper Passivation Solution

Tags

coppercopper-alloypassivationpost-etchanti-tarnish

Reveals

Not an etchant. Applied after etching to stabilize the copper surface and prevent tarnishing during examination.

Typical Results

Cu-Pass-Sol = copper(II) sulfate pentahydrate in dilute sulfuric acid. Classical acidic copper-passivation chemistry: the dissolved Cu²⁺ saturates the surface and inhibits further oxidation of the freshly etched copper during microscopy and short-term storage. Not an etchant; produces no microstructure development on its own.

Application Method

Method:Immersion (post-etch passivation)
Typical Time:5–10 s

Preparation Notes

PACE Cu-Pass-Sol (part no. CU-PASS-SOL) is supplied ready-to-use. Per-batch recipe (250 mL):

IngredientAmount
Copper(II) sulfate pentahydrate (CuSO₄·5H₂O)40.04 g
Sulfuric acid (H₂SO₄, concentrated)1.5 mL
Water (diluted to total volume)250 mL

Application Notes

After etching and water/ethanol rinse, immerse the sample 5–10 s in Cu-Pass-Sol. Rinse briefly with ethanol; air-dry. The acidic chemistry means the sample should already be in a neutral-rinse condition before passivation (rinse off etchant first).

Troubleshooting

Sample tarnishes during examination: passivation was too brief or rinse left water on the surface; redo with a longer Cu-Pass-Sol dip and ethanol-only final rinse.

Storage Notes

Glass bottle at room temperature. Stable many months. Per PACE SDS, acidic content; handle with PPE.

Alternative Etchants

  • Ethanol-only final rinse (less effective)

Similar Etchants

  • Acidic copper sulfate passivation chemistry

ASTM References

Not applicable (post-etch passivator)