Skip to main content

Commercially Pure Titanium Grade 4

Titanium Alloy

Basic Information

Category: Titanium Alloy
Material Type: metal
Alternative Names:
CP Ti Grade 4Grade 4ASTM B265
Tags:
pure-titaniumcorrosion-resistantbiomedical

Composition & Structure

Composition: Ti-0.40O-0.5Fe
Microstructure: Alpha titanium

Description

Highest strength unalloyed titanium with excellent corrosion resistance. Used in chemical processing and medical applications.

Mechanical Properties

Hardness: 200 HB
Hardness (HB): 200 HB
Hardness Category: soft
Tensile Strength: 550 MPa
Yield Strength: 483 MPa

Physical Properties

Density: 4.51 g/cm³
Melting Point: 1668 °C

Material Characteristics

Work Hardening: Yes
Magnetic: No
Corrosion Resistance: excellent

Sectioning

Use slow-speed diamond saw with continuous coolant flow. Diamond saws are preferred for titanium alloys to minimize deformation and work hardening. Standard diamond blade (0.3-0.5 mm thickness) is appropriate. Use adequate coolant flow to prevent overheating and minimize work hardening. The reactive nature of titanium requires careful handling. Cutting speed: 150-250 RPM for most diamond saws. Apply light to moderate pressure - the material can work-harden if excessive pressure is applied. Avoid forcing the cut which can cause sample damage and work hardening. Leave adequate allowance (~1-2 mm) for grinding away the heat-affected zone and any deformation from cutting.

Mounting

Cold mounting with epoxy resin is preferred to avoid heat that could affect the microstructure. Use a low-shrinkage epoxy resin for best edge retention. Ensure complete cure before grinding to prevent edge rounding and maintain sample integrity.

Hot compression mounting is acceptable if the part tolerates ~150-180°C and moderate pressure (2000-3000 psi for phenolic). Use phenolic or epoxy-phenolic resins. Ensure proper cooling under pressure to minimize shrinkage. The material requires careful handling during mounting to avoid deformation. For critical applications, ensure the mounting material is compatible with the intended use environment.

Grinding

The medium hardness (200 HB) of Commercially Pure Titanium Grade 4 requires careful grinding. Use standard SiC grinding papers with adequate water lubrication. Disc speed: 200-300 RPM. Apply light to moderate pressure (25-35 N per 30 mm sample) - avoid excessive force that could cause work hardening. Use sharp, fresh grinding papers to minimize deformation.

Grinding sequence:
  • 240 grit: Remove sectioning damage (30-60 seconds). Use moderate pressure to remove heat-affected zone.
  • 320 grit: Remove previous scratches (30-60 seconds). Ensure complete scratch removal.
  • 400 grit: Remove previous scratches (30-60 seconds). Ensure complete scratch removal.
  • 600 grit: Remove previous scratches (30-60 seconds). Ensure complete scratch removal.
Always rotate the specimen holder 90° between steps to ensure complete scratch removal. Use complementary rotation (platen and holder same direction, different speeds) rather than contra-rotation to minimize deformation. Adequate water lubrication is critical - avoid drying during grinding which can cause smearing.
Recommended Sequence:
240320400600

Polishing

The medium hardness requires careful polishing. Use diamond polishing with appropriate polishing pads for each stage. Apply light to moderate pressure throughout to prevent deformation.

Diamond polishing sequence:
  • 6μm diamond: 2-4 minutes on a medium-hard synthetic pad (e.g., TEXPAN) with light to moderate pressure (25-35 N per 30 mm sample). Start with 6μm to minimize damage. ensure complete scratch removal at each step.
  • 1μm diamond: 2-4 minutes on a medium-hard synthetic pad (e.g., TEXPAN) with light pressure (20-30 N). Continue removing scratches from previous step.
  • 0.05μm colloidal silica: 1-2 minutes on a high-napped final polishing pad (e.g., MICROPAD) with very light pressure. This removes any remaining fine scratches and prepares the surface for etching. Monitor for relief - reduce polishing time if excessive relief develops.
Use appropriate polishing lubricants. The medium material means polishing times should be sufficient but not excessive - avoid over-polishing which can cause relief and affect grain boundary revelation. Monitor the surface frequently under the microscope to check for smearing or excessive relief.
Recommended Sequence:
6μm diamond1μm diamond

Etching

Commercially Pure Titanium Grade 4 is the strongest CP grade with the highest oxygen content. The microstructure is single-phase alpha with equiaxed grains — there is no beta phase. The higher strength compared to Grades 1-3 allows slightly more aggressive etching. Kroll's Reagent (Chemical Etching) - Standard etchant:
  • Composition: 2-3ml HF + 5ml HNO₃ + 100ml H₂O
  • Preparation: Add acids to water slowly with stirring in a plastic container (HF attacks glass). Prepare fresh for best results.
  • Application: Swab for 5-10 seconds. Grade 4 tolerates standard Kroll's better than lower CP grades due to higher strength.
  • Reveals: Equiaxed alpha grain boundaries and annealing twins. Grain size assessment per ASTM E112.
  • Rinse: Immediately with water, then ethanol. Dry with compressed air.
Modified Kroll's Reagent (Chemical Etching) - For more controlled etching:
  • Composition: 1ml HF + 3ml HNO₃ + 100ml H₂O
  • Application: Swab for 10-30 seconds. Use when more controlled grain boundary etching is needed or for grain size comparison studies.
  • Reveals: Alpha grain boundaries with finer contrast control than standard Kroll's.
Etching Strategy:
  • No beta phase present — all grains are alpha; contrast comes from grain boundary etching and crystallographic orientation
  • Grade 4 tolerates standard Kroll's better than Grades 1-3 due to higher oxygen-strengthened matrix
  • Polarized light on unetched or lightly etched surfaces reveals alpha grain orientation colors
  • For grain size measurement, ensure consistent etch across the entire sample surface
Safety: HF is extremely hazardous — always use in a fume hood with HF-rated gloves, face shield, and lab coat. Have calcium gluconate gel available. Store all HF solutions in plastic containers.
Common Etchants:
Kroll's ReagentModified Kroll's

Heat Treatment

Annealed

Temperature Parameters

Annealing Temperature: 700 °C

No standards information available.

Applications

  • Chemical processing
  • Biomedical
  • Marine

Typical Uses

  • Chemical equipment
  • Medical implants
  • Heat exchangers